Sinceyou are balancing this across three phases you need to divide that by the square root of 3 (1.73) to get the amps per phase. Which will be about 104 amps. Now your seventh unit will be an additional 30 amps connected to each of the two phases you put it on, so you will have something like.
AbsoluteGenerators specializes and inventories cost-effective 3-phase power solutions from 5 kW to 100 kW. Please see our locked rotor design code guide and generator power calculator for more assistance with purchasing. Please also call in to begin working with us on your next 3-phase power need application. NEMA L16-20R (20 Amp 480)
Toconvert amps to kVA in a single-phase power system, you can use the formula S = I × V / 1000 where the amperage (I) is in amperes, the voltage (V) is in volts, and the resulting apparent power (S) is in kilovolt-amperes or kVA. On the other hand, for the 3-phase system, you can use S = I × V × √3 / 1000 for line-to-line voltage and S
Forthree phase motors, when HP is known: Where, Voltage: The phase-to-phase voltage for a 3-phase supply. Rating: The power rating of the motor in kW. Power factor (cosΦ): The rated power factor of the motor.
Foralternating currents, the 2.7 kW amp transformation is different for a single phase and a 3 phase system; the power factor is needed in both cases. In case of the three-phase electrical generation, line to line voltage and line to neutral voltage require different constants to convert 2.7 kilowatts to amps, (√ 3) and 3, respectively.
Thisformula relates the phase current I (in amps) to the power P (in kilowatts), power factor PF, and line to neutral RMS voltage VL-N (in volts). The formula states that the phase current is equal to 1000 times the power in kilowatts, divided by 3 times the power factor and the line to neutral RMS voltage.
1000kW. 8,333 amps. 120 volts. 11.1 kW to amps. 11 Kilowatts to Amps is a tool to convert 11 kilowatts to amps. To calculate how many amps in 11 kW, multiply kW to 1,000, then divide by volts.
kWSingle-phase Single-phase kW Amps at 120 V 4.9 amps at 240 V LR amps at 240 V LR amps at 120 V Refrigerator pump, sump, furnace, garage opener 0.5 0.5 4.9 2.5 13 25 1.5 Freezer, washer, septic grinder 0.75 0.75 7.4 3.7 19 38 2.3 General 1 hp 1 1 9.8 4.9 25 50 3 Well and septic lift pump 2 2 19.6 9.8 50 100 6
Kilowatt[kW] Horsepower (metric) 0.01 kW: 0.0135962162 horsepower (metric) 0.1 kW: 0.1359621617 horsepower (metric) 1 kW: 1.3596216173 horsepower (metric) 2 kW: 2.7192432346 horsepower (metric) 3 kW: 4.0788648519 horsepower (metric) 5 kW: 6.7981080865 horsepower (metric) 10 kW: 13.596216173 horsepower (metric) 20 kW:
paBr.
7.5 kw to amps 3 phase